PM 2000 & PM3000 intelligent Power Distribution units (IPDUs) support outlet level metering and switching capability to provide datacenter professionals the tools they need to monitor, reduce, and manage their growing power consumption costs of IT equipment. Thresholds can be created to allow datacenter teams to know before problems occur and minimize downtime caused by overloaded circuits.
The ability to integrate with the DSView3 management software enables IT managers to have a consolidated interface to access and manage their IT equipment and also the supporting power infrastructure. The optional DSView 3 Power Manager further enhances this by allowing historical reporting to track power consumption, capacity and cost across individual PDUs, racks, rows of racks, or entire data centers.
PM2000 / PM3000 Quick Facts
Measure and monitor power consumption per outlet
Remote switching capability to power on/off individual outlets (PM3000 models only)
Create thresholds to generate alerts/notifications
Flexible installation- IP and Serial interface options
Can be managed directly or integrated with other Avocent solutions using the DSView 3 software
Optional DSView 3 Power Manager for historical reporting
Simultaneous firmware updates
Features and Benefits
Feature
Benefit
Outlet level, phase level and strip level current metering with threshold/alert capabilities
Provides preemptive notification of any impending overload issues before they occur, and simplifies the task of installing new equipment
Capability to remotely switch outlets through onboard web interface, DSView3 management software (Not available on PM2000)
Allows power to hung up IT equipment to be recycled, turned on or turned off remotely for faster resolution time
On board web interface
Can be installed for direct access right out of the box or it can be configured as part of a larger integrated solution using the DSView 3 software.
IP and Serial interface options
Options to install by connecting directly to the network or save IP connections by using the serial interface to connect directly to Avocent appliances already connected to the network.
Daisy chaining
Saves the number of IP addresses or console / KVM ports that are required to manage all power distribution needs.
Integration with DSView 3
Single interface for management of IT equipment and iPDU’s simplifies mapping of outlets to servers and other equipment to reduce and minimizes power cycling the wrong equipment.
Integration with DSView 3 Power Manager
Track historical trends to measure and monitor IT power consumption, capacity, and cost to understand what issues exist and to make more informed decisions in the future.
Electronic Overcurrent Protection
Electronic Overcurrent protection is an added layer of protection that gets activated in the event of minor overloads. During such events, outlets get turned off first instead of the primary overcurrent protection (OCP) getting tripped.
Sequential Startup
Protects integrity of all upstream electrical infrastructure by staggering the inrush current draw of all plugged in devices.
Sequential Shutdown
Protects integrity of applications by ensuring that multiple equipment running dependant applications shut down in the appropriate order only.
Specifications
Environmental
Operating Temperature 10-50ºC
Storage Temperature -40-65ºC
Relative Humidity 20 to 80 percent operating, 5 to 95 percent non-operating
Dimensions
Form Factor 0U vertical, 1U horizontal rack mountable
Weight - 7.3 lbs (horizontal without power cord), 14.8 lbs (vertical without power cord)
Physical Dimensions (W x D x H)
Horizontal- 17 x 8.272 x 1.719 in (43.2 x 21 x 4.4 cm)
Vertical- 2.2 x 66 x 3.15 in (5.6 x 167.6 x 8 cm)
Network Connection
Number 1
Type 10/100/1000 Ethernet
Safety Markings and Approvals
UL, FCC, cUL, CE, VCCI, C-Tick, CB
Safety certifications and EMC certifications for this product are obtained under one or more of the following designations: CMN (Certification Model Number), MPN (Manufacturer’s Part Number) or Sales Level Model designation. The designation that is refrenefced in the EMC and/ or safety reports and certificates are printed on the label applied to this product.
External Sensor - Technical Specs
Temperature Sensor Range: -45 degree C to +115 degree C
Daisy chainging capability: Up to 3 sensors per PDU sensor port
External Power Required: No
Cable Type - Standard Cat5 Patch Cable
Maximum Cable Length - 1200 ft (between the PDU and the last sensor in the daisy chain)
PM3000/2000/1000 firmware compatibility: ver 1.3.0 and higher
Shipping Dimensions: 10" (W) x 7" (D) x 4" (H)
Net dimensions: 3" (W) x 3" (D) x 1.5" (H)
Unit
Input Voltage
Input Current
Output Voltage
Outlet Max Current
Bank Max Unbalanced Current
Bank Max Balanced Current
Listed Branch Circuit Protection
North America
PM2001H-401
PM3001H-401
US single phase 208-240VAC 2W + PE 60HZ
24A
208-240VAC 60Hz
16A
16A
(see note 2)
8A
30A
PM2001V-401
PM3001V-401
US single phase 208-240VAC 2W + PE 60HZz
24A
208-240VAC 60Hz
16A
16A
(see note 2)
8A
30A
PM2002H-401 PM3002H-401 PM2006H-401 PM3006H-401
US three phase
Delta 208- 240 VAC
3W + PE 60Hz
24A per phase
208-240VAC 60Hz
16A
16A
(see note 1)
13.85A
30A
PM2002V-401
PM3002V-401
PM2006V-401
PM3006V-401
US three phase
Delta 208- 240 VAC
3W + PE 60Hz
24A per phase
208-240
VAC
60 Hz
16A (C19)
12A (C13)
16A
(see note 1)
13.85A
30A
PM2005H-403
PM3005H-403
US three phase
Delta
208-240 VAC 3W + PE 60 Hz
40A per
phase
208-240VAC 60Hz
16A
32A
(see note 4)
32A
50A
PM2005V-403
PM3005V-403
US three phase
Delta
208-240 VAC 3W + PE 60 Hz
40A per
phase
208-240VAC 60Hz
16A (C19)
12A (C13)
32A
(see note 4)
32A
50A
PM2005H-404
PM3005H-404
US three phase
Delta 208- 240 VAC
3W + PE 60Hz
48A per phase
208-240VAC 60Hz
16A
32A
(see note 5)
27.71A
60A
PM2005V-404
PM3005V-404
US three phase
Delta 208- 240 VAC
3W + PE 60Hz
48A per phase
208-240
VAC
60 Hz
16A (C19)
12A (C13)
32A
(see note 5)
27.71A
60A
International
PM2003H-401 PM3003H-401
EU single
phase
220-240 VAC 2W + PE 50/60 Hz
32A
220-240VAC 50/60Hz
16A
16A
(see note 3)
10.66A
40A
PM2003V-401
PM3003V-401
EU single
phase
220-240 VAC 2W + PE 50/60 Hz
32A
220-240VAC 50/60Hz
16A (C19)
10A (C13)
16A
(see note 3)
10.66A
40A
PM2004H-401 PM3004H-401
EU three phase
WYE 220-240/381-
415 VAC
3W + N + PE 50/
60Hz
16A per phase
220-240VAC 50/60Hz
16A
16A
16A
20A
PM2004V-401
PM3004V-401
EU three phase
WYE 220-240/381-
415 VAC
3W + N + PE 50/
60Hz
16A per phase
220-240VAC 50/60Hz
16A (C19)
10A (C13)
16A
16A
20A
PM2005H-406
PM3005H-406
EU three phase
WYE 220-240/ 381-415 VAC
3W + N + PE
50/60 Hz
32A per phase
220-240
VAC
50/60
Hz
16A
32A
32A
40A
PM2005V-406
PM3005V-406
EU three phase
WYE 220-240/ 381-415 VAC
3W + N + PE
50/60 Hz
32 per phase
220-240
VAC
50/60
Hz
16A (C19)
10A (C13)
32A
32A
40A
NOTE 1: When one bank is at a maximum 16A, the other two banks shall not exceed 12A per bank.
NOTE 2: When one bank is at a maximum 16A, the other two banks shall not exceed 8A total.
NOTE 3: When one bank is at a maximum 16A, the other two banks shall not exceed 16A total.
NOTE 4: When one bank is at a maximum 32A, the other two banks shall not exceed 13A per bank.
NOTE 5: When one bank is at a maximum 32A, the other two banks shall not exceed 23A per bank.
For more information about Outlet Bank Assignment please refer to the installer/user guide.
Diagram
Photos
Click images below to view larger photo...
External Environmental Sensors
PMHD-THS
Temperature, humidity, and dry contact combo sensor
PMHD-TS
Temperature only sensor
FAQs
Question
Answer
What is the main difference between the PM 2000 and the PM 3000 products?
The PM2000 PDUs have metering capability at the outlet level and the PM3000 PDUs have both metering and switching capability at the outlet level.
What is Electronic overcurrent protection?
This is a feature built in to Avocent PM 3000 units that locks the outlets that are being unused on a phase / strip where currents have exceeded programmed thresholds.
Are PM 3000 and PM 2000 units IPv6 compliant?
Yes, through WebUI, CLI and DSView3.
Can multiple PM 3000 and PM 2000 units be daisy chained?
Yes, up to a total of 5 units or 128 outlets, whichever comes first. They can be daisy chained with either Cyclades PM units or with other PM 3000 or PM 2000 units.
What are the different ways to remotely manage PM 3000 and PM 2000 units?
PM 3000 and PM 2000 units can be managed the following ways:
Stand alone using the Onboard web interface
CLI through a serial connection
Serially connected to ACS 6000 console serves
Serially connected to current KVM over IP switches
Centrally managed using the DSView3 management software and optional DSView3 Power Manager for real-time and historical reports.
Do PM3000 and PM 2000 units have an accessory to hold the output power cords connected to IEC outlets?
Delhi: K-1/12, Ground Floor,
Chittaranjan Park
New Delhi - 110019.
Tel. : +91-11-2627 3412
Mobile : +91-93130 91055
E mail : rajiv.taneja@avocent.co.in